MIX MASTER LEVEL CONTROL adjusts the level of the main mix XLR outputs feeding the sound system. This does not affect the monitor output or the meter reading.
On the MIX / MONITOR METERS, the main meters follow the selected monitor source.
The meter reads '0' for an XLR output of +4dBu. The mixer should be operated with these meters averaging around '0' with loudest peaks no higher than '+6'.
In SPLIT CUE mode, whilst a channel cue button is pressed, the left meter will display the CUE level and the right meter will display the PROGRAM (PRG) level.
BOOTH MASTER LEVEL CONTROL adjusts the level of the signal to the stereo monitor RCA output. This does not affect the headphones. The monitor output could be used for a booth monitor, recording or an additional feed.
There are two HEADPHONES OUTPUTS, Stereo 1/4" TRS jack and 3.5mm mini-jack.
MONITOR LEVEL CONTROL adjusts the level of the headphone signal. The head phone level can be further trimmed up or down in level in the Advanced Setup Menu.
CUE / ADD MIX CONTROL pans between Cue signal and the Main Mix output. Turned fully anti-clockwise, only the active Cue signal is heard through the headphones when a Cue is selected. Gradually turning clockwise introduces the Main Mix output to the Cue signal until, fully clockwise, only the Mix is heard.
This does not affect the meters. Split Mode pans Left (Cue) to Right (Mix).